CONTROL AND MEASURING SYSTEMS MD SERIES
To fit the most demanding materials testing requirements.
Direct measuring / control of load, displacement, deformation and any other measurable variable.
The combination of these control modules, with the WINTEST software, assures a friendly use and configuration method with reliable test results data acquisition and management.
| MD2 | MD58 | |||
|---|---|---|---|---|
| Static Test Up to 4 channels | Dynamic applications High accuracy static machines Calibration machines More than 4 channels |
|||
| Type of Tests - Compression - Tension Cycles | Type of Tests All the described for the MD2 adding the following: - Waves (sinus) - Only compression - Only tension - Passing through zero (tension-compression) - Fatigue |
|||
| Machines - Electromechanic - Hydraulic | Machines - Electromechanic - Hydraulic |
|||
| Most common materials /products - Cement - Concrete - Steel - Other metals - Composites, plastics & rubbers | Most common materials /products - Steels - Weldings - Railways - Elastomeric materials - Final products |
|||
| Software compatibility - Wintest.met: metals - Wintest.hor: concrete - Wintest.cem: cement - Wintest.mad: wood - Elect.met: electromechanic machines | Software compatibility All static versions of wintest and: - Elect.met: electromechanic machines |
|||
MD2 MODULE
Standard electronic system for data acquisition and control of IBERTEST materials testing machines.
- Stand alone or computer operated

- Digital control
- Up to 1000 readings per second and per channel
- Sychronous channels
- High load resolution: ±180.000 points
- One unique measuring range
- Transducer calibration with every start up
- VFast connection to PC via Ethernet

TECHNICAL SPECIFICATIONS
| Processor | Processor AMD 520, 133 MHz |
|---|---|
| Minimum cycle time in closed loops | 1 ms |
| Control frequency | 1 kHz |
| PC communications interface | USB 2.0 full speed and Ethernet 10/100 Mbit |
| Load Resolution | + 180.000 steps, two measuring ranges 2mV/V and 4mV/V |
| Encoder-SSI input channel | Squared input max 32 MHz App. 300 kHz |
| Digital inputs at 24 volts | 8 |
| Digital outputs at 24 volts | 8 |
| Serial sensor interface | COM1 (internal) |
| Debug interface | COM2 115 kB |
| Option to synchronize data acquisition and movement control with additional units | Yes, possible |
| Optional slot for safety screen | Yes |
| 12 Bus extension slots | Optional, two |
| Power supply | 24V dc |
| Drive Interface | + 10V (16Bit), analogue command output I/O's and relays for safety functions |
| RS485 Interface | For external Keyboard / Display, supports a maximum of 4 devices |
MD58 MODULE
- Could work directly or remote via a PC. Even when the computer fails the test could be carried out.
- The control over order machine components (servo valve, servo motor, etc) is fully digital simplifying the adjusting process (PID adjust, calibration, etc) which could be done from the software.
- Up to 5000 readings per second and per channel
- Sychronous channels
- Up to 8 slots for expansion, where up to 7 auxiliary channels could be mounted. The first channel is reserved for the load measure. Additional digital channel for displacement transducer.
- Calibration parameters are loaded in the EPROM memory, avoiding recalibrations after new hardware or software installations

TECHNICAL SPECIFICATIONS
| Processor | Processor AMD 520, 133 MHz |
|---|---|
| Minimum cycle time in closed loops | 0,2 ms |
| Control frequency | 5 kHz |
| PC communications interface | USB 2.0 full speed and Ethernet 10/100 Mbit |
| Load Resolution | + 180.000 steps, two measuring ranges 2mV/V and 4mV/V |
| Encoder-SSI input channel | Squared input max 32 MHz App. 300 kHz |
| Digital inputs at 24 volts | 8 |
| Digital outputs at 24 volts | 8 |
| Serial sensor interface | COM1 (internal) |
| Debug interface | COM2 115 kB |
| Option to synchronize data acquisition and movement control with additional units | Yes, optional |
| Optional slot for safety screen | Yes, optional |
| Analogic Inputs / Outputs | 1 preinstalled input for load cell 1 analogical output 0-10V 7 slots for 6 auxiliary additional channels |
| Drive Interface | Command outputs + 10V with + 15 Bit resolution. Digital outputs I/O's and relays for safety functions |
| Power Supply | c.a. 100 - 250 V |
COMMUNICATION DIAGRAMS

REMOTE CONTROL UCR-D
Digital remote control unit in magnetic box, which connects to the electronic command module and allows
movements of the mobile crossbar (RAISE, LOWER, STOP) and autonomous test programming by means of function and numeric keys (input value and programming) and a digital potentiometer to position the mobile crossbar, menu navigation and data entry. A 128x64 LCD graphic screen allows the programming and test results to be displayed.
The magnetic box allows the unit to be fitted anywhere in the test area (maximum operability and user comfort).
- Dimensions: L 26 x B 120 x H 200 mm
- Display: LCD 128x64 Pixel
- Connections: MD2, MD58 with 3 meters cable
- Keys: UP, DOWN and STOP (machine control), numerical and funtions keys (valve input, programming) emergency stop
- Digipoti: Crosshead- / cylinder positioning.Scroll of display and cursor positioning of data input
DEVICES USING MD MODULES